EJ-FG09 universal battery tester and capacity measurement

//EJ-FG09 universal battery tester and capacity measurement
EJ-FG09 universal battery tester and capacity measurement 2018-02-13T07:08:32+00:00

Project Description

ADVANTAGES


(1) Remaining power of the real capacity, high-precision capacity indicator
(2) LCD Green Backlight automatically open
(3) Power-down memory
(4) Adapt to the ultra- high-power load
(5) High sensitivity
(6) Low power consumption

DISPLAY


(1) Remaining battery capacity (Ah or mAh);
(2) Battery SOC;
(3) Battery voltage;
(4) Battery current value;
(5) Output power value;
(6) Remaining time of charging and discharging.

Application:
The EJ-FG09 battery tester is suitable for lithium battery, lithium iron phosphate battery, lead-acid battery and nickel-metal hydride battery which voltage is from 10V to 100V.

Working interface:
1. Upper left corner to display the percentage of the residual capacity;
2. Upper right corner displays the initial capacity (Ah/mAh);

3. The battery symbol on the middle left, the residual capacity displayed as a visualized totem;
4. The remained charging or discharging time in the middle right, the max value is 99:00:00;
5. Voltage, current, and power displayed on the bottom.

Install:
1.Open one rectangular orifice and two screw holes on the panel of the equipment;
2.Then install the battery tester from the back of the panel, and put the shell of tester into the rectangular orifice;
3.Finally, fix the battery tester with tapping screws from the front of the panel. As shown below:

Connect:
1. Prepare a shielded wire and an ordinary wire (0.3-0.75 mm²);
2. One end of the ordinary wire connects to B+ of battery;
3. Another end connects to B+ of sampler (anyone is ok);
4. The B- of sampler connects to B- of battery;
5. P- of sampler connect to P- of output;
6. Finally, connect sampler to battery tester by the shielded wire.

Attention: Please connect as shown strictly. The sampler must be connected to the negative circuit, it is forbidden to connect to the positive circuit. If you want to extend the shielded wire, you must use 4 lines of the same specification.
This the length of the shielded wire is 0.5m. And 1m, 2m, 3m, 4m, 5m, 8m, 10m can select, Please contact us in advance. The price is according to the length.

Parameter
Min
Type
Max
Unit
Working voltage
10.0
100.0
V
Working dissipation
12.0
20.0
mA
Standby dissipation
5
8
mA
Capacity accuracy
±2.0
Voltage accuracy
±2.0
Current accuracy
±2.0
%
Backlight on current
80.0
100.0
mA
Backlight off current
50.0
60.0
mA
Preset capacity value
0.1
999.0
Ah
Current of 50A sampler
50.0
75.0
A
Temperature range
0
20
35
Weight
200
g
Size
86×54×22
mm
Parameter
Min
Type
Max
Unit
Working voltage
10.0
100.0
V
Working dissipation
12.0
20.0
mA
Standby dissipation
5
8
mA
Capacity accuracy
±1.0
Voltage accuracy
±1.0
Current accuracy
±1.0
%
Backlight on current
80.0
100.0
mA
Backlight off current
50.0
60.0
mA
Capacity setting value
0.1
999
Ah
Current of 50A sampler
50.0
150.0
A
Temperature range
0
20
35
Weight
120.0
g
Size
86×54×22
mm
Parameter
Min
Type
Max
Unit
Working voltage
10.0
100.0
V
Working dissipation
12.0
20.0
mA
Standby dissipation
5
8
mA
Capacity accuracy
±1.0
Voltage accuracy
±1.0
Current accuracy
±1.0
%
Backlight on current
80.0
100.0
mA
Backlight off current
50.0
60.0
mA
Capacity setting value
0.1
999.0
Ah
Current of 50A sampler
50.0
500.0
A
Temperature range
0
20
35
Weight
410.0
g
Size
86×54×22
mm
Parameter
Min
Type
Max
Unit
Working voltage
10.0
100.0
V
Working dissipation
12.0
20.0
mA
Standby dissipation
5
8
mA
Capacity accuracy
±2.0
Voltage accuracy
±2.0
Current accuracy
±2.0
%
Backlight on current
80.0
100.0
mA
Backlight off current
50.0
60.0
mA
Preset capacity value
0.1
999.0
Ah
Current of 50A sampler
50.0
750.0
A
Temperature range
0
20
35
Weight
680
g
Size
86×54×22
mm