EJ-FG01 battery tester

//EJ-FG01 battery tester
EJ-FG01 battery tester 2018-02-13T06:52:03+00:00

Project Description

ADVANTAGES

(1) Remaining battery capacity display true high precision capacity indicator;
(2) Opens automatically when you use the backlight function
(3) Down Memory Function
(4) Adapt super power load
(5) High sensitivity
(6) Low Power

DISPLAY

(1) remaining battery capacity (Ah or mAh);

(2) the capacity of the percentage and the totem pole display;

(3) battery voltage;

(4) battery current value;

(5) output power value;

(6) for charging and discharging the remaining time.

Note: This product contains 50A sampler, 1 m shielded cable( default 1m, 0.5m, 2m, 3m, 4m, 5m, 8m, 10m can select, Please contact us in advance). The price is according to the length.

Working interface:

1. Upper left corner displays the percentage of the residual capacity;
2. Upper right corner displays the initial capacity (Ah/mAh);
3. The battery symbol on the middle left, the residual capacity displayed as a visualized totem;
4. The remained charging or discharging time in the middle right, the max value is 99:00:00;
5. Voltage, current, and power displayed on the bottom.

Connect:
We need a shielded wire and an ordinary wire (0.3-0.75 mm²) to connect the battery monitor with the sampler.
1. Connect one end of the ordinary wire to B+ of battery;
2. Connect another end of the ordinary wire to B+ of sampler (anyone is ok);
3.Connect B- of sampler to B- of the battery;
4. Connect P- of sampler to P- of output;
5. Finally, connect sampler to battery monitor by the shielded wire.

 

Connection diagram of 50A sampler

Attention: Please connect as shown strictly. The sampler must be connected to the negative circuit, it is forbidden to connect to the positive circuit. If you want to extend the shielded wire, you must use 4 lines of the same specification.

Install:

1. First, open one rectangular orifice and two screw holes on the panel of the equipment;
2. Then install the battery monitor from the front of the panel, and put the shell of monitor into the rectangular orifice;
3. Finally, fix the monitor with tapping screws from the front of the panel. As shown above.

Parameter
Min
Type
Max
Unit
Working voltage
8.0
80.0
V
Working dissipation
10.0
12.0
mA
Standby dissipation
0.5
0.8
mA
Sleep dissipation
50
60
uA
Voltage acquisition accuracy
±1.0
%
Current acquisition accuracy
±1.0
%
Backlight on current
40
50
mA
Capacity setting value
0.1
590.0
Ah
Current of 50A Sampler
0.0
50.0
75.0
A
Temperature range
0
20
35
Size
52*36*15.6
mm
Weight
70
g
Parameter
Min
Type
Max
Unit
Working voltage
8.0
80.0
V
Working dissipation
10.0
12.0
mA
Standby dissipation
0.5
0.8
mA
Sleep dissipation
50
60
uA
Voltage  accuracy
±1.0
%
Current  accuracy
±1.0
%
Backlight on current
40
50
mA
Battery capacity setting value
0.1
999.0
Ah
Sampler working current
0.0
50.0
150.0
A
Using temperature range
0
20
35
Size
52*36*15.6
mm
Weight
220
g